Products
Lead Wire DC Bistable Solenoid Coil
  • Lead Wire DC Bistable Solenoid CoilLead Wire DC Bistable Solenoid Coil
  • Lead Wire DC Bistable Solenoid CoilLead Wire DC Bistable Solenoid Coil
  • Lead Wire DC Bistable Solenoid CoilLead Wire DC Bistable Solenoid Coil

Lead Wire DC Bistable Solenoid Coil

Our Lead Wire DC Bistable Solenoid Coil is designed for DC-powered mechanisms that need to switch between two stable positions without continuous coil energization.
Operating Voltage: Common options include 6V, 12V and 24V DC; 3V–48V DC available upon request.
Switching Control: Single-coil polarity-reversing or dual-coil configuration.
Typical Stroke: 2–15 mm, depending on the design.
Holding Force: Typically 1–20 N or higher, depending on frame size and construction.
Lead Wire Design: Flexible connection and customized lead length.
Protection: IP65 available for applicable overmolded designs.
Customization: Voltage, stroke, holding force, insulation class, dimensions and materials.

    The Lead Wire DC Bistable Solenoid Coil uses a permanent magnet to maintain either of two stable positions after a short electrical pulse. Continuous power is not required to hold the selected position, reducing standby power consumption and heat generation.

    The coil is available in single-coil and dual-coil configurations. Lead wire length, operating voltage, stroke, holding force, dimensions and insulation materials can be customized to match the equipment and control circuit.

    Overmolding is available for applications requiring additional protection against dust and moisture. IP65 protection can be provided for applicable designs, subject to finished-product testing.

    Specifications and Customization

    Parameter

    Specification

    Operating Voltage

    3–48V DC, subject to design confirmation

    Stroke

    Typically 2–15 mm

    Holding Force

    Typically 1–20 N or higher

    Switching Configuration

    Single coil or dual coil

    Pulse Duration

    Typically 20–100 ms, depending on load and design

    Insulation Class

    Class B (130°C) or Class H (180°C), subject to model confirmation

    Bobbin Material

    Nylon, PPS or PBT

    Lead Wire Insulation

    QA or QZY, subject to specification confirmation

    Encapsulation

    Vacuum impregnation or overmolding

    Protection Rating

    IP65 available for applicable overmolded designs

    Final specifications depend on the coil construction, mechanical load, stroke and operating conditions.

    Switching Configurations

    Single-Coil Design

    A single coil switches between two positions through pulse polarity reversal. It requires a compatible control circuit to change the current direction.

    Dual-Coil Design

    Two separate coils control the switching directions. Each coil receives a pulse to move the mechanism to its corresponding position.

    The choice between single-coil and dual-coil configurations depends on the control circuit, wiring arrangement and available installation space.

    Applications

    Typical applications include:

    • Smart metering
    • Battery-powered equipment
    • Electronic locking systems
    • Latching mechanisms
    • HVAC control systems
    • Selected medical equipment
    • Industrial control mechanisms

    Selection should consider the required stroke, holding force, switching frequency, installation dimensions and operating environment.

    Manufacturing Process and Quality Control

    Precision Coil Winding

    Automatic multi-spindle, semi-automatic multi-spindle and single-spindle winding machines accommodate different wire sizes and winding specifications. Turn count, winding tension and layer arrangement are controlled according to the approved design.

    Orthocyclic winding is available for compatible coil designs to achieve a compact and orderly wire arrangement.

    Lead Wire Connection

    Winding wires are connected to the specified lead wires using the designated joining process. Connection points are insulated according to the product requirements.

    Encapsulation

    Vacuum impregnation uses epoxy or polyester resin to improve insulation and mechanical stability.

    Overmolding encloses the coil in a protective housing. Available materials include nylon PA66, PBT and BMC, with PPS available for compatible designs. Material selection depends on operating temperature, electrical requirements and environmental conditions.

    Final Inspection and Testing

    Finished coils are inspected according to applicable product specifications. Tests may include electrical performance, dimensional checks, functional switching and high-voltage withstand testing.

    High-voltage testing capability can exceed 1500V under specified test conditions. The actual test voltage depends on the coil design and agreed requirements.

    Lead Wire DC Bistable Solenoid Coil

    Lead Wire DC Bistable Solenoid CoilLead Wire DC Bistable Solenoid Coil

    Manufacturing Process

    Solenoid Coil Manufacturing Process

    Quality Certifications

    The company holds ISO 9001, IATF 16949 and applicable CE-related certifications or compliance documentation. Certification scope and validity should be confirmed against the relevant current documents.

    Solenoid Coil Quality CertificationSolenoid Coil Quality Certification

    Frequently Asked Questions

    1. What DC voltages are available?

    Common options include 6V, 12V and 24V DC. Other voltages from 3V to 48V DC can be evaluated according to the coil design and performance requirements.

    2. Can the stroke and holding force be customized?

    Yes. Stroke and holding force can be specified according to the required movement and mechanical load. Typical reference ranges are 2–15 mm and 1–20 N or higher, depending on the design.

    3. Can the lead wire length and coil dimensions be customized?

    Yes. Lead wire length, coil dimensions, mounting arrangement and materials can be customized according to the application requirements.

    4. Does the coil require continuous power?

    No. The permanent magnet maintains either stable position after the switching pulse ends. Electrical power is only required during switching.

    5. Is IP65 protection available?

    Yes. IP65 is available for applicable overmolded designs, subject to verification of the finished construction and lead-wire interfaces.

    6. What information is required for a quotation?

    Please provide the operating voltage, stroke, holding force, switching configuration, lead wire length, installation dimensions and order quantity. Drawings or samples can also be supplied for technical evaluation.

    Request a Quote

    For a customized Lead Wire DC Bistable Solenoid Coil, send us your technical drawing, sample or product specifications. Our team can review the electrical parameters, switching configuration, mechanical dimensions and encapsulation requirements before production.

    Send Inquiry
    Contact Info
    • Address

      No. 7, Yongan Road, Xikou Industrial Zone, Fenghua District, Ningbo City, Zhejiang Province, China

    If you have any enquiry about quotation or cooperation, please feel free to email us  or use the following inquiry form.Our sales representative will contact you within 24 hours. Thank you for your interest in our products.
    X
    We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
    RejectAccept