Products
2-Way Normally Closed DC Solenoid Valve Assembly
  • 2-Way Normally Closed DC Solenoid Valve Assembly2-Way Normally Closed DC Solenoid Valve Assembly
  • 2-Way Normally Closed DC Solenoid Valve Assembly2-Way Normally Closed DC Solenoid Valve Assembly
  • 2-Way Normally Closed DC Solenoid Valve Assembly2-Way Normally Closed DC Solenoid Valve Assembly

2-Way Normally Closed DC Solenoid Valve Assembly

The 2-Way Normally Closed DC Solenoid Valve Assembly integrates a DC solenoid coil and armature into a pre-assembled unit for installation on a compatible main valve body. It is designed for applications requiring a normally closed flow path when electrical power is removed.
Valve configuration: 2-way, normally closed.
Power supply: DC, voltage to be confirmed.
Assembly: Solenoid coil and armature, with internal components according to the selected configuration.
Installation: Mounting interface to match the main valve body.
Customization: Voltage, coil power, pilot port and mounting interface, subject to design feasibility.

    The 2-Way Normally Closed DC Solenoid Valve Assembly combines the electromagnetic actuator and associated valve components into one assembled unit. Instead of sourcing and fitting the coil and armature separately, you receive a matched assembly designed around the specified mounting interface and operating requirements.

    In the normally closed configuration, the valve's closed position is maintained when the coil is de-energized. When the correct DC voltage is applied, the magnetic force moves the armature and actuates the valve mechanism. Once power is removed, the return mechanism moves the assembly back toward its closed position.

    This operating principle makes the assembly suitable for systems that require electrical control of fluid or gas flow, provided the selected valve design is compatible with the medium, pressure, temperature and operating conditions.

    The complete assembly also simplifies component handling during installation. Coil and armature compatibility can be addressed before delivery, reducing the need for separate component matching and on-site assembly. Final compatibility depends on the main valve design and the confirmed technical specifications.


    How the Normally Closed Configuration Works

    Power off — closed position

    When the coil is not energized, the return mechanism keeps the valve in its normally closed state. The flow path is closed according to the valve's design.

    Power on — valve actuated

    When the specified DC supply is applied, the coil generates a magnetic field that moves the armature. The resulting movement actuates the valve mechanism and opens the controlled flow path.

    Power removed — return to closed

    When electrical power is removed, the magnetic force decreases and the return mechanism moves the armature back toward the closed position.

    The actual opening and closing response depends on the coil specification, armature design, valve structure, operating pressure and medium. For applications involving safety shutdown, hazardous media or critical process control, the complete valve system should be evaluated for the required fail-safe behavior.

    Quick selection guide:

    Need the valve to stay open when power is off? → Choose  Normally Open

    Need the valve to stay closed when power is off? → Choose  Normally Closed 

    Not sure? → Most safety and process applications use  Normally Closed for fail-safe shut-off


    Key Features and Practical Benefits

    Integrated Coil and Armature

    The coil and armature are supplied as a matched assembly rather than separate components. This helps simplify installation planning and reduces the need to manage separate component interfaces.

    Normally Closed Operation

    The valve is designed to return to its closed state when electrical power is removed. This is useful where the control system requires a default closed position, subject to the main valve's mechanical design and operating conditions.

    DC Coil Configuration

    The DC coil can be specified for the intended control power supply. The required voltage, power consumption, duty cycle and electrical connection should be confirmed before ordering to ensure compatibility with the control system.

    Application-Specific Configuration

    Voltage, coil power, pilot port arrangement and mounting interface can be discussed against the actual application requirements. Any changes to the internal structure or external dimensions require technical confirmation.


    Technical Specifications

    The following information should be confirmed for the exact model before an order is placed.

    Item

    Specification

    Product name

    2-Way Normally Closed DC Solenoid Valve Assembly

    Valve configuration

    2-way, normally closed

    Actuation

    Electromagnetic

    Coil supply

    DC

    Rated voltage

    To be confirmed

    Coil power

    To be confirmed

    Insulation class

    To be confirmed

    Duty cycle

    To be confirmed

    Response time

    To be confirmed by model

    Operating pressure range

    To be confirmed for the complete valve

    Operating temperature

    To be confirmed

    Compatible medium

    To be confirmed

    Port and mounting dimensions

    According to the selected configuration

    Electrical connection

    To be confirmed

    Applicable certifications

    Subject to the specific product and certification scope

    Important: The operating pressure, temperature range, medium compatibility and sealing performance depend on the complete valve design, not the solenoid coil alone. Please confirm these requirements before selecting the assembly.


    Certification

    We have obtained ISO 9001, IATF 16949, CE, and other relevant certifications to ensure product quality and compliance with international standards.

    Our quality management system follows strict manufacturing and inspection procedures throughout the entire production process, from raw material selection and component processing to assembly, testing, and final delivery.These certifications demonstrate our commitment to continuous quality improvement, reliable production control, and providing high-quality solenoid pilot heads and solenoid coils for global customers.

    2-Way Normally Closed DC Solenoid Valve Assembly2-Way Normally Closed DC Solenoid Valve Assembly


    FAQ

    1.  Why DC for normally closed?

    DC power is the preferred choice when the application requires fast response, silent operation, or when the system is battery-powered. For normally closed solenoid armature, DC offers key advantages:

    Faster opening – 10-50ms response time means the valve opens quickly when power is applied, critical in emergency and precision control scenarios

    Predictable force – constant current provides consistent magnetic force, no inrush spikes to manage in the control circuit

    Silent operation – no hum, making it suitable for noise-sensitive environments like hospitals, laboratories, and office buildings

    Battery compatibility – DC is the standard for battery-powered systems, making integration straightforward

    Simple control – basic on/off switching is all that is needed

    2.  Why would I choose a pilot assembly instead of buying a coil and solenoid armature  separately?

    Our pre-assembled valve assembly eliminates the need for you to handle separate components, match interfaces, or worry about assembly tolerances. We supply the coil and  solenoid armature as a complete, factory-aligned, and pre-tested unit. You receive one part number, one delivery, one warranty – and it is ready to mount directly onto your main valve body. This simplifies procurement, reduces inventory, and eliminates assembly risks.

    3.  Does a DC coil produce heat during operation?

    Yes, but it is manageable. Since DC current is constant, the coil generates continuous heat when energized. For normally closed armature, this means the coil heats up whenever the valve is held open. We use Class H (180°C) insulation as standard, with higher temperature options available. If your application requires the valve to stay open for extended periods, consider:

    Using a low-power version to reduce heat generation

    Selecting a higher insulation class (Class N, 200°C)

    Ensuring adequate ventilation around the coil

    Using pulse-width modulation (PWM) to reduce holding current



    Send Inquiry
    Contact Info
    • Address

      No. 7, Yongan Road, Xikou Industrial Zone, Fenghua District, Ningbo City, Zhejiang Province, China

    If you have any enquiry about quotation or cooperation, please feel free to email us  or use the following inquiry form.Our sales representative will contact you within 24 hours. Thank you for your interest in our products.
    X
    We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
    RejectAccept