Ningbo Anlite Machinery Co., Ltd. manufactures solenoid coils for industrial applications that require controlled winding parameters and consistent electrical performance. Coil specifications can include enamelled wire with different thermal ratings, from H class (180°C) to R class (220°C), depending on the application and approved design.
Winding parameters are established during production setup and controlled according to the approved specifications. Any authorised changes are documented to help maintain consistency between production batches and reduce the risk of deviations in the finished coil.
Winding, encapsulation and performance testing are carried out at Anlite's workshops in Xikou, Ningbo. Keeping these processes at one site supports production coordination and traceability from the winding stage through encapsulation to final inspection.
Selecting an insulation class involves more than choosing enamelled wire. The complete insulation system, including wire enamel, encapsulation materials and lead insulation, must be suitable for the specified operating temperature and application conditions. For designs operating near their thermal limits, the insulation system should be evaluated against the actual working environment and approved technical requirements.
Solenoid coils are available with DIN connectors or lead connections, with protection options up to IP65 or IP67, depending on the design. The required protection level should be selected according to the installation environment, including exposure to dust, moisture, coolant or cleaning water.
For applications requiring IP67 protection, the complete assembly and its applicable test evidence should be checked against IEC 60529. The connector interface, encapsulation and cable entry all affect the protection of the finished coil. Confirm the required protection rating and test conditions when specifying a custom design.
Each solenoid coil undergoes electrical and magnetic testing before packing. Production records can be traced through Anlite's ERP, PLM and MES systems, linking relevant manufacturing information to the production order.
For OEM projects that require PPAP documentation, the available documentation can be discussed during project review. Depending on the agreed requirements, this may include material certificates, process flow documentation and a control plan. Documentation availability and submission scope should be confirmed before order placement.
Coil performance depends on the surrounding magnetic circuit and the operating requirements of the valve or actuator. A solenoid coil can be paired with our Solenoid Armature Assembly for evaluation as a matched unit. This allows relevant operating characteristics, such as stroke, holding force and response time, to be assessed against the agreed design requirements.
For projects requiring a more integrated solution, Anlite also produces Solenoid Valve Assembly products. Discussing the coil, armature and valve requirements together can help clarify interface dimensions, electrical specifications and validation needs before production.
Anlite has developed more than 1,000 models for industrial automation, automotive and medical equipment applications. Custom solenoid coil projects can be reviewed against the customer's electrical specifications, mechanical interfaces and operating conditions.
To evaluate a custom design, provide the available information on rated voltage, duty cycle, ambient temperature, connector type and installation dimensions. Drawings, the target application and other relevant operating requirements are also useful. The engineering team can then review feasibility, insulation class selection and sample lead time.
Once the specifications are approved, the corresponding technical drawings and production requirements can be used as references for repeat orders. Any design changes should be reviewed and recorded to maintain alignment with the approved version.
Solenoid coils are supplied to overseas customers from Ningbo, China. Lead times are quoted according to the approved specifications, order quantity and production schedule. After-sales support covers technical enquiries, failure analysis and replacement planning, subject to the project requirements.
Compliance documents and declarations, including RoHS, REACH, CE or UL-related documentation where applicable, should be confirmed for the specific product and destination market. Anlite's stated quality management certifications include IATF 16949 and ISO 9001; relevant certificate scope and validity can be provided for verification.
Send your solenoid coil specifications, technical drawing or application requirements to sales1@anlite.cn. Include the rated voltage, duty cycle, operating temperature, connection type and required protection rating where available.
Based on the information provided, the quotation can address pricing, sample lead time, technical feasibility and the proposed insulation class. If some parameters have not yet been finalised, share the available details for an initial engineering review.