The Lead Wire AC Explosion-proof Solenoid Coil is designed for solenoid valves operating in hazardous environments where flammable gases, vapors, or combustible dust may be present. Its explosion-proof construction helps prevent internal sparks or excessive heat from igniting the surrounding atmosphere. It is suitable for applications in oil refineries, chemical plants, natural gas facilities, paint booths, grain storage, and mining operations.
Our Lead Wire AC Explosion-Proof Solenoid Coils are designed for use in hazardous atmospheres where flammable gases, vapors, or combustible dust may be present. The flameproof enclosure (Ex d) contains any internal ignition and prevents it from spreading to the surrounding environment, ensuring safe operation in potentially explosive conditions.
The lead wire design allows control circuits and power supplies to be placed outside the hazardous area, with the coil installed directly on the valve in the field. This separation improves system safety and simplifies maintenance.
At present, we have 5 types of Lead Wire AC explosion-proof coils with different hole diameters and heights.
ALTC3917 Explosion-proof coil
Product Parameters:
Inner Diameter: φ 9.3mm
Height: 30.3mm
Normal Voltage: 110V/220V AC
Normal Power: 6.5VA
Lead Wire: 1.6m
Explosive-proof Class: Ex mb IIC T4 Gb/Ex mb IIIC T30 ℃ Db
IP Grade: IP65
Insulation Class: H
ALTC3918 Explosion-proof coil
Product Parameters:
Inner Diameter: φ 13.3mm
Height: 40.8mm
Normal Voltage: 110V/220V AC
Normal Power: 15VA
Lead Wire: 1.6m
Explosive-proof Class: Ex mb IIC T4 Gb/Ex mb IIIC T30 ℃ Db
IP Grade: IP65
Insulation Class: H
ALTC3919 Explosion-proof coil
Product Parameters:
Inner Diameter: φ 14.3mm
Height: 43.7mm
Normal Voltage: 110V/220V AC
Normal Power: 23VA
Lead Wire: 1.6m
Explosive-proof Class: Ex mb IIC T4 Gb/Ex mb IIIC T30 ℃ Db
IP Grade: IP65
Insulation Class: H
ALTC3920 Explosion-proof coil
Product Parameters:
Inner Diameter: φ 16.3mm
Height: 41.3mm
Normal Voltage: 110V/220V AC
Normal Power: 26VA
Lead Wire: 1.6m/2.5m
Explosive-proof Class: Ex mb IIC T4 Gb/Ex mb IIIC T30 ℃ Db
IP Grade: IP65
Insulation Class: H
ALTC3921 Explosion-proof coil
Product Parameters:
Inner Diameter: φ 20.5mm
Height: 63.3mm
Normal Voltage: 110V/220V AC
Normal Power: 50VA
Lead Wire: 1.6m/2.5m
Explosive-proof Class: Ex mb IIC T4 Gb/Ex mb IIIC T30 ℃ Db
IP Grade: IP65
Insulation Class: H
Other voltages can be customized.
Our Lead Wire AC Explosion-proof Solenoid Coil has passed the inspection and testing conducted by the National Quality Supervision and Testing Center for Explosion-Protected Electrical Products (China) and is certified as qualified. It adopts a flameproof encapsulation (Ex mb) construction, in which all electrical components are encapsulated within a metal housing with protective devices incorporated.
Applicable Locations:
l Ex mb I Mb – suitable for coal mine gas (methane) environments
l Ex mb II C T4 Gb – suitable for Zone 1 and Zone 2 locations where explosive gas mixtures of flammable gases, vapors, and air are present, for Groups IIA, IIB, and IIC, Temperature Class T1 to T4
l Ex mb III C T130°C Db – suitable for Zone 21 and Zone 22 locations with conductive combustible dust, where the maximum surface temperature does not exceed 130°C
Normal Operating Conditions:
a) Atmospheric pressure: 80 – 110 kPa
b) Ambient temperature: –20°C to +45°C
c) Relative humidity: ≤95% (at +25°C)
d) Installed in locations without significant vibration or impact
Manufacturing Process
Certification
We have obtained ISO 9001, IATF 16949, CE, and other relevant certifications to ensure product quality and compliance with international standards.
Our quality management system follows strict manufacturing and inspection procedures throughout the entire production process, from raw material selection and component processing to assembly, testing, and final delivery.These certifications demonstrate our commitment to continuous quality improvement, reliable production control, and providing high-quality solenoid pilot heads and solenoid coils for global customers.
FAQ
1. What's your s pecification review and requirement analysis ?
After receiving the customer's inquiry, we will first confirm the technical requirements in detail with the customer, including:
Electromagnetic parameters: such as wire diameter, number of turns, resistance, inductance, and rated voltage/current
Thermal performance requirements: such as the insulation class and duty cycle of the coil
Material specifications: Specific models of materials such as frames, leads, and plastic-coated materials
If we are unable to obtain detailed and comprehensive specification requirements from the customer, we will inquire about the working conditions, temperature, frequency, etc. of the product's usage, and provide the customer with a solution.
2. Will you provide samples?
After understanding the customer's requirements and receiving the sample order from the customer, we start to produce the samples. The passing of the sample test is the standard for mass production. If mold opening is required, 3D printed samples can be chosen. After the samples are completed, we will conduct preliminary tests first. The tests usually include: Electrical performance tests, inter-turn withstand voltage tests, temperature rise tests, mechanical strength tests, etc
Only when the samples fully meet the standards will they be approved to enter the mass production stage.
3.Will you conduct the final quality inspection and testing?
After completing all the procedures, we conduct a comprehensive quality inspection and high-pressure resistance test. The high voltage can reach over 1500V.
If you have any enquiry about quotation or cooperation, please feel free to email us or use the following inquiry form.Our sales representative will contact you within 24 hours. Thank you for your interest in our products.
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy