Products
2-Way Normally Open DC Solenoid Valve Assembly
  • 2-Way Normally Open DC Solenoid Valve Assembly2-Way Normally Open DC Solenoid Valve Assembly
  • 2-Way Normally Open DC Solenoid Valve Assembly2-Way Normally Open DC Solenoid Valve Assembly

2-Way Normally Open DC Solenoid Valve Assembly

The 2-Way Normally Open DC Solenoid Valve Assembly combines a DC solenoid coil and solenoid armature into one factory-assembled unit, reducing the need for separate component sourcing and in-house assembly.
Valve function: 2-way, normally open configuration.
Installation: Designed for a compatible main valve body.
Common voltage options: 12VDC and 24VDC.
Customization: Other voltage and power specifications available upon request.

    Our 2-Way Normally Open DC solenoid  valve assembly is a complete control unit that combines our DC solenoid coils and 2-Way Normally Open solenoid armature into a single factory assembly package. It is designed to be directly installed on the main valve body provided by the customer or purchased separately, converting it into a fully functional 2-way normally open solenoid valve.

    2-Way Normally Open DC Solenoid Valve Assembly


    Key features of supplying as an assembly

    Factory alignment – the armature and pilot orifice are precisely set at the factory, eliminating field adjustment and ensuring consistent performance

    Single mounting step – install one unit onto your main valve, not two separate components

    Reduced inventory – stock one assembly part number instead of separate coils and solenoid armature

    Simplified ordering – one purchase order, one delivery, one warranty


    Technical Specifications

    Item

    Specification

    Product name

    2-Way Normally Open DC Solenoid Valve Assembly

    Valve configuration

    2-way, normally open

    Assembly components

    DC solenoid coil and solenoid armature

    Operating power

    DC

    Common voltage options

    12VDC, 24VDC

    Other voltage options

    Customization available

    Main valve body

    Supplied separately or provided by the customer, subject to project arrangement

    Mounting interface

    To be confirmed against the main valve body

    Other electrical parameters

    Confirmed according to the selected design

    Pressure range, flow capacity, media compatibility and operating temperature should be confirmed for the applicable valve configuration.


    How the Assembly Works

    When energized, the solenoid coil generates an electromagnetic field that moves the armature and operates the valve mechanism.

    In a normally open configuration, the valve is designed to remain open in its specified de-energized state and change state when the solenoid is energized. The exact flow-control process depends on the main valve construction.

    For pilot-operated designs, the armature may control a pilot orifice that directs pressure to operate the main valve diaphragm or piston. This principle should be verified against the specific design.


    Manufacturing and Quality Control

    Our production process covers incoming material inspection, coil winding, component assembly and final inspection.

    Incoming materials undergo IQC inspection. Depending on the product requirements, sample testing may include electrical performance, inter-turn withstand voltage, temperature rise, mechanical strength and functional switching.

    The coil and armature are assembled into one unit, with applicable electrical and functional checks carried out against the agreed specifications. Inspection items and acceptance criteria depend on the product design.

    2-Way Normally Open DC Solenoid Valve Assembly2-Way Normally Open DC Solenoid Valve Assembly


    2-Way Normally Open DC Solenoid Valve Assembly

     

    Quality Certifications

    We hold ISO 9001, IATF 16949, CE and other relevant certifications, subject to the scope and applicability of each certification.

    Our quality management procedures cover material inspection, manufacturing control, assembly and final testing. Product inspection requirements are determined by the approved specifications and agreed acceptance criteria.

    2-Way Normally Open DC Solenoid Valve Assembly2-Way Normally Open DC Solenoid Valve Assembly


    Why Choose the Assembly Format?

    Factory-Assembled Unit

    Separate Components

    Coil and armature supplied together

    Coil and armature supplied separately

    Less in-house assembly work

    Assembly handled by the customer

    One assembly reference for ordering

    Separate items to identify and manage

    Configuration reviewed before ordering

    Compatibility managed during assembly

    The main benefit is a simpler component supply and assembly process. Compatibility with the main valve body must still be confirmed before purchase.


    Before You Order

    To help us evaluate compatibility, please provide any available information:

    Main valve body drawing, model or sample

    Mounting dimensions and connection details

    Required coil voltage and power specifications

    Intended valve operation and application conditions

    If a complete drawing is unavailable, an existing sample or interface dimensions can provide a starting point for technical review.

    We can review the supplied information and identify any specifications that need to be finalized before quotation or sample development.


    Frequently Asked Questions

    1. What information is required to select this assembly?

    The most useful information is the main valve body drawing or sample, mounting interface, required DC voltage and intended valve operation. These details help establish compatibility before ordering.

    2. Can it be installed on my existing main valve body?

    The assembly is designed for a compatible main valve body. Compatibility depends on mounting dimensions, connection details and operating requirements. Please provide a drawing, model number or sample for review.

    3. What does normally open mean?

    A normally open valve is designed to remain open in its specified de-energized state. Energizing the solenoid changes the mechanism's position. The exact operating sequence depends on the valve design.

    4. What voltage options are available?

    Commonly manufactured options include 12VDC and 24VDC. Other voltage and power specifications can be evaluated according to project requirements.

    5. What is the minimum order quantity?

    For regular products, 1,000 pieces per batch is the standard quotation reference quantity.

    Customized projects can be considered from 1 piece, subject to design feasibility, material availability, tooling and setup requirements. Unit pricing depends on the order quantity and project specifications.


    Request a Quote

    Looking for a 2-Way Normally Open DC Solenoid Valve Assembly for your existing valve body?

    Send us your drawing, sample, mounting dimensions or required coil voltage. We can review compatibility requirements and confirm the next steps for quotation or sample evaluation.



    Send Inquiry
    Contact Info
    • Address

      No. 7, Yongan Road, Xikou Industrial Zone, Fenghua District, Ningbo City, Zhejiang Province, China

    If you have any enquiry about quotation or cooperation, please feel free to email us  or use the following inquiry form.Our sales representative will contact you within 24 hours. Thank you for your interest in our products.
    X
    We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
    RejectAccept