Connector options: DIN 43650 / EN 175301-803 interfaces, Form A and Form B, subject to model configuration
Customization: Rated voltage, power, coil dimensions, bobbin material and housing construction
Material options: Nylon, PPS, PBT and BMC, depending on design requirements
Manufacturing support: Sample development, tooling preparation, coil winding, encapsulation and electrical inspection
Please provide the valve model, connector configuration, rated voltage, power requirements and installation dimensions when requesting a quotation.
The DIN connector design provides a standardized electrical connection between the solenoid coil and its matching plug. Compared with a coil using separate lead wires, this configuration can simplify installation, replacement and electrical connection during equipment maintenance.
Form A and Form B connectors have different interface dimensions and configurations. The correct version must be selected according to the mating plug and the solenoid valve manufacturer's specifications. Connector type alone does not guarantee compatibility with every valve brand or model.
Hydraulic and pneumatic solenoid valves
Industrial automation and machine control
Fluid control equipment
Mobile machinery and related control systems
The final selection depends on the valve design, operating voltage, power rating, duty cycle, ambient temperature and installation conditions.
The coil construction can be configured according to the electrical, thermal and mechanical requirements of the application.
Winding wire: Class H (180°C) magnet wire is specified in the supplied product information. The applicable wire specification and insulation system should be confirmed for the selected model.
Bobbin materials: Nylon, PPS and PBT are available options, subject to the coil design and required operating conditions.
Housing and encapsulation: Thermoplastic overmolding and BMC are available construction options. Material selection depends on the required insulation, dimensional stability, temperature resistance and mechanical protection.
The final material combination should be confirmed against the application's temperature range, electrical requirements and environmental exposure.
When DC power is applied to the winding, the coil generates a magnetic field. The resulting electromagnetic force acts on the solenoid's movable armature or plunger, enabling the associated valve or mechanism to operate.
When the power supply is interrupted, the magnetic field decays and the movable component returns according to the mechanism's design, typically through spring force or another return arrangement.
The coil generates the magnetic force; the movement and switching behavior of the complete assembly also depend on the armature, spring, valve structure, supply conditions and mechanical load.
For applications involving frequent switching or continuous energization, the rated voltage, coil resistance, power consumption, duty cycle and heat dissipation must be considered together

Before sample development, the required electrical and mechanical parameters are reviewed with the customer. These may include:
Rated voltage, power, resistance and inductance
Wire specification and winding requirements
Insulation class and duty cycle
Connector type and installation dimensions
Bobbin, lead terminal and housing material requirements
If the initial drawings or specifications are incomplete, the operating environment and application requirements should be clarified before the design is finalized.
Samples are produced according to the confirmed specifications. Where tooling is required, 3D-printed samples may be considered for preliminary evaluation, depending on the design.
The supplied manufacturing process identifies the following potential inspection items:
Electrical performance
Inter-turn withstand voltage
Temperature rise
Mechanical strength
The applicable test methods, acceptance criteria and results should be established for the specific model. Sample approval should precede mass production when required by the agreed project process.
Production fixtures are prepared to support coil positioning, winding consistency and dimensional control. Fixture requirements depend on the coil geometry, winding pattern and production volume.

Incoming materials are checked against the applicable specifications before production. Materials identified in the manufacturing process include enameled wire, bobbins, terminals, insulating components and lead materials where applicable.
Inspection records and acceptance criteria should correspond to the approved bill of materials and supplier requirements.
Coil winding is a key manufacturing stage because wire diameter, turn count, winding tension and layer arrangement affect the coil's electrical characteristics and dimensional consistency.
The available production equipment includes fully automatic multi-spindle winding machines, semi-automatic multi-spindle winding machines and semi-automatic single-spindle winding machines.
Multi-spindle equipment supports the simultaneous winding of multiple coils, while single-spindle equipment can accommodate certain special winding patterns and customized designs.
Orthocyclic winding may be used where appropriate to arrange adjacent turns in a regular, compact pattern. Its suitability and resulting performance depend on the wire diameter, bobbin geometry, winding parameters and process control.

The winding ends are connected to the designated electrical terminals according to the product design. Connection methods, joint insulation and terminal construction depend on the selected DIN connector coil configuration.
Where separate lead wires are used within the design, the connections require suitable insulation and protection against short circuits.
The encapsulation method is selected according to the design and application requirements.
Vacuum impregnation: Resin is used to penetrate accessible voids within the winding structure and improve insulation. The resulting properties depend on the resin system and curing process.
Overmolding: The coil is enclosed in a molded housing. Available material options include thermoplastics such as PA66 and PBT, and BMC for designs requiring different thermal or dimensional characteristics.
The appropriate process depends on the required protection, temperature conditions, mechanical design and production requirements. An IP rating should only be stated for a configuration that has been appropriately verified.


Completed coils undergo final inspection according to the applicable product specifications and quality requirements.
The supplied process includes high-voltage withstand testing, with a stated test voltage exceeding 1,500 V. The actual test voltage, duration, acceptance criteria and applicable standard should be confirmed for the specific model before publication or technical approval.
Additional inspection items may be defined according to the product requirements, including electrical characteristics, dimensions and visual condition.
Customization is available for selected design parameters, subject to engineering review and manufacturing feasibility.
|
Parameter |
Information to Confirm |
|
Connector configuration |
Form A, Form B or specified mating interface |
|
Rated voltage |
Required DC supply voltage |
|
Power rating |
Rated power or current requirement |
|
Coil dimensions |
Drawing or dimensional specification |
|
Winding parameters |
Electrical specifications and design requirements |
|
Bobbin material |
Nylon, PPS, PBT or another approved material |
|
Housing construction |
Thermoplastic overmolding, BMC or specified alternative |
|
Operating conditions |
Ambient temperature, duty cycle and environmental exposure |
|
Validation requirements |
Electrical, thermal and mechanical tests required for approval |
For replacement applications, please provide the existing coil part number, valve model, connector photographs and dimensional drawing where available. These details help establish whether the proposed coil matches the original assembly.
Certification and compliance claims should be verified against the relevant certificate, product scope and applicable standard.
The original product information lists ISO 9001, IATF 16949, CE and RoHS-related compliance. The specific certificate holder, validity, scope and applicability to the offered coil should be confirmed before these claims are used as product-level assurances.
UL recognition of an individual component or winding wire should not be presented as certification of the complete solenoid coil unless the applicable certification documentation supports that claim.
Relevant documents can be reviewed during technical evaluation, subject to availability and the scope of the applicable certification.

It is an electromagnetic coil designed for connection through a compatible DIN-style plug interface. When energized by a DC supply, the coil generates a magnetic field that actuates the associated solenoid mechanism.
The solenoid coil generates the electromagnetic force. A solenoid valve is a complete assembly that uses this force to control fluid flow. A replacement coil must match the valve's electrical and mechanical requirements.
Check the mating connector, interface dimensions and valve manufacturer's specifications. Form A and Form B are not interchangeable solely because both use DIN-style connectors.
Customization may be possible if the required electrical and mechanical specifications can be established. Provide the valve model, existing coil part number, rated voltage, power requirements, dimensions and connector details for evaluation.
The most useful starting information is the required quantity, connector configuration, rated voltage, power rating, coil dimensions and application. Drawings, photographs and existing part numbers can help clarify the requirements.
The inspection plan should be based on the approved specifications and applicable acceptance criteria. Depending on the design, it may include electrical performance, inter-turn withstand voltage, temperature rise, mechanical strength and final visual or dimensional inspection.
Suitability depends on the rated power, insulation system, ambient temperature, heat dissipation and specified duty cycle. Continuous operation should be confirmed against the technical specifications of the selected model.
Send us your valve model, connector type, rated voltage, power requirements and dimensional drawing. Our team can review the available specifications and determine the information needed for sample development or a customized quotation.
Address
No. 7, Yongan Road, Xikou Industrial Zone, Fenghua District, Ningbo City, Zhejiang Province, China
Tel